This is a demo store. No orders will be fulfilled.
AP8459EU3
APC Rack PDU 2G, Metered-by-Outlet, ZeroU, 16A, 230V, (21) C13 & (3) C19
£1,037.10
Limited Stock: Only 1 available
Rack PDU 2G, Metered-by-Outlet, ZeroU, 16A, 230V, (21) C13 & (3) C19
Description
APC Metered by Outlet Rack Power Distribution Units (PDUs) provide individual outlet power metering to enable energy optimization and circuit protection Current metering provides real-time remote monitoring of connected loads Metered by Outlet Rack PDUs provide power utilization data to allow Data Center Managers to make informed decisions on load balancing and right sizing IT environments to lower total cost of ownership Metered by Outlet Rack PDUs include real power monitoring, a temperature/humidity sensor port, locking IEC receptacles, and ultra low profile circuit breakers Users can access and configure Metered by Outlet Rack PDUs through secure Web, SNMP, or Telnet Interfaces which are complimented by APC Centralized Management platforms using InfraStruxure Central, Operations, Capac...ity, and Energy EfficiencySpecifications
Design | |
---|---|
PDU types | Metered, Metered-by-outlet |
Mounting | Vertical |
Product colour | Black |
Certification | EN 55022 Class A, EN 55024, EN 61000-3-2, EN 61000-3-3, FCC Part 15 Class A, ICES-003, UL Listed, VCCI Class A, VDE REACH |
Rack capacity | 0U |
Ports & interfaces | |
AC outlets quantity | 24 AC outlet(s) |
AC outlet types | C13 coupler, C19 coupler |
Power plug | IEC309 |
Output connections | 21 x C13 & 3 x C19 |
Features | |
Cable length | 3 m |
LED indicators | Yes |
Certification | EN 55022 Class A, EN 55024, EN 61000-3-2, EN 61000-3-3, FCC Part 15 Class A, ICES-003, UL Listed, VCCI Class A, VDE REACH |
Management features | |
Monitoring | Current, Power, Voltage |
Ergonomics | |
Cable length | 3 m |
LED indicators | Yes |
Power | |
---|---|
Maximum power | 3680 W |
Nominal input voltage | 200-230 V |
Nominal output voltage | 230 V |
Maximum current | 16 A |
Maximum total current draw per phase | 16 A |
Maximum input current per phase | 16 A |
Load capacity | 3680 VA |
AC input frequency | 50 - 60 Hz |
Weight & dimensions | |
Dimensions (WxDxH) | 56 x 51 x 1829 mm |
Weight | 6.76 kg |
Package weight | 9.03 kg |
Package dimensions (WxDxH) | 163 x 117 x 2037 mm |
Packaging data | |
Package weight | 9.03 kg |
Package dimensions (WxDxH) | 163 x 117 x 2037 mm |
Operational conditions | |
Operating temperature (T-T) | -5 - 45 °C |
Storage temperature (T-T) | -25 - 65 °C |
Storage relative humidity (H-H) | 5 - 95% |
Operating relative humidity (H-H) | 5 - 95% |
Operating altitude | 0 - 3000 m |
Non-operating altitude | 0 - 15000 m |
Technical details | |
Compliance certificates | RoHS |